Formulas used to calculate electrical characteristics
Connecting windings in series:
- Inductance = Inductance(table) × (number of windings)2
- DCR = DCR(table) × number of windings
- Isat = (Isat(table) × 6) ÷ number of windings connected in series
- Irms = Irms(table)
Connecting windings in parallel:
- Inductance = Inductance(table)
- DCR = 1 ÷ [number of windings × (1 ÷ DCR(table))]
- Isat = (Isat(table) × 6) ÷ number of windings connected in series
- Irms = Irms(table) × number of windings
Create a 130 Watt, 1:1, two switch forward converter transformer
Choose HPH6-2400L
Vin = 36 – 57 Vdc; Vout = 12 V, 10.8 A
Part number |
Inductance (µH) |
Percent Tolerance |
DCR max (Ω) |
Volt-time product (V-µs) |
Irms (A) |
HPH6-2400L_ |
194 |
25 |
0.03 |
131.9 |
2.9 |
Connecting primary windings in parallel:
When primary windings (Wpri) are connected in parallel, DCR
decreases, Irms increases, and inductance and volt-time product remain the same.
Example: For HPH6-2400L, connect three primary windings in parallel:
- Inductance = Inductance(table) = 194 μH
- DCR = 1 ÷ [Wpri × (1 ÷ DCR(table))] = 1 ÷ [(3 × (1 ÷ 0.030]) = 0.010 Ohms
- VT = VT(table) = 131.9 V-μsec
- Irms = Irms(table) × Wpri = 2.90 × 3 = 8.70 A
Connecting secondary windings in parallel:
When secondary windings (Wsec) are connected in parallel, DCR decreases and Irms increases.
Example: For HPH6-2400L, connect three secondary windings in parallel:
- DCR = 1 ÷ [Wsec × (1 ÷ DCR(table))] = 1 ÷ [(3 × (1 ÷ 0.030)] = 0.010 Ohms
- Irms = Irms(table) × Wsec = 2.90 × 3 = 8.70 A